Wall-Mounted Type Ultrasonic Flowmeter
The AFT Ultrasonic Flowmeter widely used to measure different kinds of liquid. Transmitter and transducer install seperately.Transmitter can install at indoor,Instrument cabinet,Dashboard. Transducer install on the pipes. Transmitter and Transducer connect by special cable. It can realize to measure flow.Connect with temperature sensor,it can measure heat flow. Widely used in Running water,Heating, Water conservation,Metallurgy,Chemical industry,Machinery,Energy etc. Used for production monitoring, water balance testing, thermal equilibrium network commissioning, energy monitoring. It is most important flow measure instrument during manufacturing process
Key Benefits
- Good stability and high precision
- Fast networking and long transmission distance
- High protection level, high cost performance
- Multiple displays, convenient and simple operation
- Strong anti-interference ability
- Powerful automatic memory function
- Support SD card memory: It can realize mass storage by the ultrasonic flow meter
Product Description
The measuring principle of electromagnetic flowmeter is based on Faraday’s law of electromagnetic induction. The sensor is mainly composed of a measuring tube with an insulating lining, a pair of electrodes installed by inserting the measuring tube wall, a pair of coils, and an iron core to generate a working magnetic field. When a conductive fluid flows through the measuring tube of the sensor, a voltage signal proportional to the average flow rate of the fluid will be induced on the electrode. The signal is operationally amplified and processed to achieve various display functions.
Key feature:
- Select different model sensors, can achieve DN15-DN6000mm pipe flow measurement
- Adopt low voltage,multi-pulse radiating circuit. Accuracy, Lifetime and Reliability are better.
- Adopt double-balanced signal differential transmission, receiving circuit, effectively resist the drive, tower, Strong power lines and other sources of interference.
- Automatic memory the cumulative flow of 512 days before, 128 months before, 10 years before. Automatic memory the power-on and off of 64times before and the flow. Automatic memory the meter working condition of 32 days before.
- With integrated structure, measurement can be completed at the measuring point, which conforms to the usage habits of most instruments, and the structure is more reasonable
- Using double-balanced signal differential transmitting and receiving circuits, effectively resisting strong interference sources such as frequency converters, TV towers, high-voltage lines, etc.
- using ordinary cables, the transmission distance can reach more than 1000 meters, and the networking is very convenient and fast. This transmission method has strong anti-interference ability, and solves the problems of high cost, poor anti-interference ability, and short transmission distance of special cables for split ultrasonic flowmeters.
Application Range
The wall-mounting flow meter can be applied to a wide range of pipe flow measurements. Applicable liquids include pure liquids as well as liquid with small quantity of tiny particles.
- Water (hot water, chilled water, city water, sea water, waste water, etc.)
- Sewage with small particle content
- Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.)
- Chemicals (alcohol, acids, etc.)
- Plant effluent
- Beverage, liquid food
- Ultra-pure liquids
Technical Specification
# | Item Name | Parameter Values |
---|---|---|
1 | Applicable Medium | Drinking water, river water, sea water, ground water, cooling water, high temperature water, sewage, lubricating oil, diesel oil, fuel oil, chemical liquids, other homogeneous fluids. |
2 | Explosion-proof grade | EXdⅡBT6 |
3 | Pipe Material | Metal (such as carbon steel, cast iron, stainless steel, aluminum, etc.) non-metallic materials (such as PVC, organic glass, etc.) |
4 | Working Humidity | Transmitter:85%RH;transmitter protection grade:IP68;Water Depth<2m |
5 | Working Temperature | Transmitter:-20~60 ℃;Transducer:-30~160 ℃ |
6 | Cable | Normal below 50m;Select RS485 Communication,Transmission distance can over thousand meters |
7 | Data Interface | Isolated RS485 interface, can upgrade flowmeter through PC,support modbus |
8 | Power Supply | DC8-36V or AC85-264V |
9 | Consumption | 1.5W |
10 | Tube lining material | FRP, mortar, rubber, etc. |
11 | Sensor protection level | IP68 |
12 | Converter protection level | Wall-mounted converter: IP65 Panel-mounted converter: IP52 Integrated converter: IP67 |
Ordering Details
Just need 1 pcs
5 pcs/3 days, 10 pcs/5 days, 50 pcs/10 days
Courier delivery, by sea, by air
Qingao, Tianjin, Shanghai, Shenzhen
T/T, L/C, Paypal, Terms of Payment
12 Months