Threaded Turbine Flowmeter
Approved by:CE, SIL-3, ATEX Explosion-proof certification
-
Nominal Sizes: DN4~DN40
-
Thread Type: Standard G thread (other thread types customizable)
-
Accuracy Grades: ±1%R standard; ±0.5%R and ±0.2%R optional
-
Repeatability: 0.05%–0.2%
-
Range Ratio: 1:10 / 1:15 / 1:20 (depending on model)
-
Medium Temperature: −20 °C to +120 °C (depending on model)
-
Ambient Temperature: −10 °C to +55 °C (display) / up to +60 °C (transmitter)
-
Pressure Rating: Up to 6.3 MPa (higher ratings available by request)
- Digital Communication: RS-485 (Modbus RTU), HART (optional)
-
Explosion-Proof Grade: Exd IIB T6 or Exia II CT4 (depending on configuration)
-
Ingress Protection: IP65 standard; higher available on request
-
Standard Compliance: JB/T 9246-1999 (Turbine Flow Sensor Standard)
-
High measuring accuracy: Provides standard accuracy of ±1% (up to ±0.5% or ±0.2% optional), ensuring consistent measurement in demanding industrial processes.
-
Excellent repeatability: Stable readings (0.05–0.2% repeatability), so small changes in flow can be seen clearly.
-
Wide rangeability: Range ratio up to 1:10 or higher (model-dependent), so one meter can cover normal and low flows.
-
Compact Threaded Design: Lightweight, small body with threaded connection enables easy installation in confined or modular systems.
-
Fast Response and High Signal Resolution: High-frequency output (3–4 kHz typical) ensures responsive measurement and excellent signal definition.
-
Wide Compatibility with Liquids: Suitable for clean, particle-free liquids with low viscosity, including water, alcohol, fuel, and solvents.
-
Multi-Signal Output Options: Choose from pulse, 4–20 mA, or digital RS-485/HART communication for flexible system integration.
-
Power Flexibility: Operates with internal lithium battery for standalone display or 24 VDC external power for continuous signal transmission.
-
Reliable Data Retention – Intelligent LCD models store totalized data for years even after power loss.
-
High-pressure capable: Threaded bodies are available for higher pressures, so you don’t have to tap the flow body.
-
Explosion-proof versions: For hazardous areas, explosion-proof models can be selected to meet plant safety needs.
-
Low maintenance: Simple internal structure makes cleaning and periodic inspection straightforward.
-
Intelligent integrated version with local LCD and battery
-
24 VDC transmitter version with 4–20 mA + pulse
-
RS-485 / Modbus communication module
-
Explosion-proof housing
-
Upstream strainer and flow straightener
-
Mating threaded unions / adapters
-
Measurement of clean water, demineralized water, or cooling water in small pipelines
-
Light oil, diesel, aviation kerosene, and other low-viscosity petroleum products
-
Alcohols and low-viscosity organic liquids in chemical plants
-
Dosing / batching systems on skid equipment
-
Boiler make-up lines and HVAC water branches
-
Industrial equipment with built-in threaded process connections
-
Flow monitoring in small OEM machines and test benches